CF LIQUID
Previous
Next
Two-layer casting compound to be applied as thermal conductive layer
Compensatory casting compound for residential and commercial buildings
CompactFloor LIQUID is a two-layer casting compound. An approximately 2 mm thick contact layer levels and fills the voids, the 8 mm thin base layer with integrated fibers ensures a stable and level surface.
Castlebutsch systems GmbH Christian Lueders 36, St. Dminka Street, Victoria, VCt 9030,
Malta – EU
E: cl@castlebutsch.com
P: 00356-79059697
VAT-ID: MT23208819
Registration Nr. C 66839
Tax No.: 996972937
Lorem ipsum dolor sit amet, consectetur adipiscing elit. Ut elit tellus, luctus nec ullamcorper mattis, pulvinar dapibus leo.
The result: High flexibility – walkable after 24 hours and after a drying time of 7 days, all common floorings can be laid.
- Easy processing – can compensate for partial unevenness
- Shorter construction – walkable after 24 hours
- Suitable for all floorings (tile, carpet, parquet, laminate, design flooring)
Any floor covering
![](http://castlebutsch.com/wp-content/uploads/2021/10/cp26.jpg)
Layered structure: Drywall floor heating, CF LIQUID, Flooring
Thermal output
Thermal output on the basis of DIN EN 1264 Average heating water temperature θm = 35°C Spread σ = 5 K | Floor heating (e.g. System IDEAL) Installation gap = 250 mm | Floor heating (e.g. System IDEAL) Installation gap = 125 mm | ||||
Room temperature θi = 20°C | Room temperature θi = 24°C | Room temperature θi = 20°C | Room temperature θi = 24°C | |||
Tiles (Rλ,B = 0.00 m²K/W) | 83.3 W/m² | 60.6 W/m² | 110.8 W/m² | 80.6 W/m² | ||
Parquet, Laminate, Design flooring (Rλ,B = 0.05 m²K/W) | 61.9 W/m² | 45.0 W/m² | 77.2 W/m² | 56.2 W/m² | ||
Carpet (Rλ,B = 0.10 m²K/W) | 49.3 W/m² | 35.9 W/m² | 59.3 W/m² | 43.2 W/m² | ||
Velour, Ready-to-lay parquet | 41.0 W/m² | 29.8 W/m² | 48.2 W/m² | 35.0 W/m² |
Cooling capacity
Cooling capacity on the basis of DIN EN 1264 Average cooling water temperature θm = 18°C Spread σ = 3 K | Floor heating (e.g. System IDEAL) Installation gap = 250 mm | Floor heating (e.g. System IDEAL) Installation gap = 125 mm | ||||
Room temperature θi = 24°C | Room temperature θi = 26°C | Room temperature θi = 24°C | Room temperature θi = 26°C | |||
Tiles (Rλ,B = 0,00 m²K/W) | 23.2 W/m² | 31.2 W/m² | 28.6 W/m² | 38.5 W/m² | ||
Parquet, Laminate, Design flooringg (Rλ,B = 0,05 m²K/W) | 18.6 W/m² | 25.1 W/m² | 22.3 W/m² | 30.0 W/m² | ||
Carpet (Rλ,B = 0,10 m²K/W) | 15.6 W/m² | 21.0 W/m² | 18.3 W/m² | 24.6 W/m² | ||
Velour, Ready-to-lay parquet (Rλ,B = 0,15 m²K/W) | 13.4 W/m² | 18.0 W/m² | 15.5 W/m² | 20.8 W/m² |