The new generation of dry screeds for residential and office buildings
The cf PRO 12 fiber cement board is a conductive layer for underfloor heating in dry construction. The flat panels are laid floating, are suitable for almost any type of flooring and enable a highly responsive underfloor heating system. Low installation height, low inertia, hoigh heat output and suitability for any flooring – these are the benefits of an underfloor heating with cf PRO 12.
- Dry installation – simple laying, glued profiled fold connection
- Thin and robust – only 12 mm installation height with 3.0 kN load capacity
- Flexibility in flooring – any flooring, also tiles up to 60 x 60 cm or 100 x 100 cm with additional glass fabrics
Castlebutsch systems GmbH Christian Lueders 36, St. Dminka Street, Victoria, VCt 9030,
Malta – EU
E: cl@castlebutsch.com
P: 00356-79059697
VAT-ID: MT23208819
Registration Nr. C 66839
Tax No.: 996972937
Lorem ipsum dolor sit amet, consectetur adipiscing elit. Ut elit tellus, luctus nec ullamcorper mattis, pulvinar dapibus leo.
Thermal conductive layer as dry screed substitute based on cement
![](http://castlebutsch.com/wp-content/uploads/2021/10/cp8.jpg)
Layered structure: Drywall floor heating, cf PRO 12, Flooring
Thermal output
Thermal output on the basis of DIN EN 1264 Average heating water temperature θm = 35°C Spread σ = 5 K | Floor heating (e.g. System IDEAL) Installation gap = 250 mm | Floor heating (e.g. System IDEAL) Installation gap = 125 mm | ||||
Room temperature θi = 20°C | Room temperature θi = 24°C | Room temperature θi = 20°C | Room temperature θi = 24°C | |||
Tiles (Rλ,B = 0.00 m²K/W) | 66.9 W/m² | 48.7 W/m² | 87.8 W/m² | 63.8 W/m² | ||
Parquet, Laminate, Design flooring (Rλ,B = 0.05 m²K/W) | 52.4 W/m² | 38.1 W/m² | 65.3 W/m² | 47.5 W/m² | ||
Carpet (Rλ,B = 0.10 m²K/W) | 43.1 W/m² | 31.3 W/m² | 52.0 W/m² | 37.8 W/m² | ||
Velour, Ready-to-lay parquet (Rλ,B = 0.15 m²K/W) |
Cooling capacity
Cooling capacity on the basis of DIN EN 1264 Average cooling water temperature θm = 18°C Spread σ = 3 K | Floor heating (e.g. System IDEAL) Installation gap = 250 mm | Floor heating (e.g. System IDEAL) Installation gap = 125 mm | ||||
Room temperature θi = 24°C | Room temperature θi = 26°C | Room temperature θi = 24°C | Room temperature θi = 26°C | |||
Tiles (Rλ,B = 0.00 m²K/W) | 19.8 W/m² | 26.6 W/m² | 24.4 W/m² | 32.9 W/m² | ||
Parquet, Laminate, Design flooring (Rλ,B = 0.05 m²K/W) | 16.4 W/m² | 22.0 W/m² | 19.7 W/m² | 26.5 W/m² | ||
Carpet (Rλ,B = 0.10 m²K/W) | 14.0 W/m² | 18.8 W/m² | 16.5 W/m² | 22.2 W/m² | ||
Velour, Ready-to-lay parquet (Rλ,B = 0.15 m²K/W) | 12.2 W/m² | 16.4 W/m² | 14.2 W/m² | 19.1 W/m² |